{"id":66,"date":"2022-01-31T20:50:06","date_gmt":"2022-01-31T20:50:06","guid":{"rendered":"https:\/\/www.aprotex.com\/?page_id=66"},"modified":"2024-08-14T16:19:09","modified_gmt":"2024-08-14T16:19:09","slug":"fire-alarms","status":"publish","type":"page","link":"https:\/\/www.aprotex.com\/index.php\/fire-alarms\/","title":{"rendered":"Fire Alarms"},"content":{"rendered":"<div id=\"cs-content\" class=\"cs-content\"><div class=\"x-section e66-e1 m1u-0\"><div class=\"x-row x-container max width e66-e2 m1u-1 m1u-2 m1u-3\"><div class=\"x-row-inner\"><div class=\"x-col e66-e3 m1u-8 m1u-9\"><hr class=\"x-line e66-e4 m1u-c m1u-d\"\/><div class=\"x-text x-content e66-e5 m1u-f\">An Aprotex fire alarm control panel (FACP) utilizes the latest in a series of innovative, microprocessor-controlled fire detection devices. Each panel has a built-in programmer, self-diagnostics and remote upload\/download capability. All circuits are inherent power limited.<\/div><\/div><div class=\"x-col e66-e6 m1u-8 m1u-9 m1u-a\"><span class=\"x-image e66-e7 m1u-g\"><img decoding=\"async\" src=\"https:\/\/www.aprotex.com\/wp-content\/uploads\/2024\/08\/Smoke-Detector.jpg\" width=\"600\" height=\"315\" alt=\"Image\" loading=\"lazy\"><\/span><\/div><\/div><\/div><div class=\"x-row x-container max width e66-e8 m1u-1 m1u-2 m1u-4\"><div class=\"x-row-inner\"><div class=\"x-col e66-e9 m1u-8 m1u-b\"><hr class=\"x-line e66-e10 m1u-d m1u-e\"\/><\/div><\/div><\/div><div class=\"x-row x-container max width e66-e11 m1u-1 m1u-2 m1u-5\"><div class=\"x-row-inner\"><div class=\"x-col e66-e12 m1u-8 m1u-9 m1u-a\"><span class=\"x-image e66-e13 m1u-g\"><img decoding=\"async\" src=\"https:\/\/www.aprotex.com\/wp-content\/uploads\/2024\/08\/firetruckfront.png\" width=\"521\" height=\"931\" alt=\"Image\" loading=\"lazy\"><\/span><\/div><div class=\"x-col e66-e14 m1u-8 m1u-9\"><div class=\"x-text x-content e66-e15 m1u-f\"><p>Detection:<\/p>\n<p>FACP\u2019s vary in size in both Class A and Class B detection zones that support waterflow devices, smoke detectors, heat detectors, manual pull stations and other detection devices as required. To enhance reliability, individual zones can be programmed for fire verification, retard delay, cross zoning and fire supervision.<\/p>\n<p>Notification: On-Site<\/p>\n<p>FACP\u2019s can provide needed power for bells, horns and strobes. Optional circuits can be easily added to FACP to supply even more power. Outputs can be programmed for Steady, Pulsed, Temporal Code 3 or California School Code. FACP\u2019s also provide outputs to control additional notification options.<\/p>\n<p>Notification: Off-Site<\/p>\n<p>Commercial FACP\u2019s have built in dual phone line and digital communicator modules to provide supervision of two phone lines and communication to our Central Station. Programming options permit individual selection of Alarms, Supervisory\/Trouble, Backup, and Recall Test reports to our Central Station.<\/p>\n<p>Control<\/p>\n<p>As a user interface, several options are available. An LED style keypad annunciations Alarm and Trouble conditions by individual zone. An LCD style keypad uses alphanumeric text to identify individual zones and zone status by name and event. Both keypad styles support one man Walk Test and Fire Drill features.<\/p><\/div><\/div><\/div><\/div><div class=\"x-row x-container max width e66-e16 m1u-1 m1u-2 m1u-6\"><div class=\"x-row-inner\"><div class=\"x-col e66-e17 m1u-8 m1u-9\"><hr class=\"x-line e66-e18 m1u-d m1u-e\"\/><\/div><\/div><\/div><div class=\"x-row x-container max width e66-e19 m1u-1 m1u-2 m1u-7\"><div class=\"x-row-inner\"><div class=\"x-col e66-e20 m1u-8 m1u-9\"><div class=\"x-text x-content e66-e21 m1u-f\"><ul>\n<li>Class A and Class B Zones<\/li>\n<li>2-Wire Smoke Zones<\/li>\n<li>Resettable 4-Wire Smoke Output<\/li>\n<li>Auxiliary power, Notification Power<\/li>\n<li>Alarm\/Trouble contacts<\/li>\n<li>4 Seconds average test signal connect time<\/li>\n<li>Event History<\/li>\n<li>One Man Walk Test<\/li>\n<li>UL 864\/NFPA 72 Central Station Signals<\/li>\n<\/ul><\/div><\/div><div class=\"x-col e66-e22 m1u-8 m1u-9\"><div class=\"x-text x-content e66-e23 m1u-f\"><ul>\n \t<li>24 or 12 volt operation<\/li>\n \t<li>Power limited<\/li>\n \t<li>Upload\/Download programming<\/li>\n \t<li>Smoke Verification<\/li>\n \t<li>Cross Zoning<\/li>\n \t<li>Remote Annunciation<\/li>\n \t<li>NFPA 72A Local<\/li>\n \t<li>NFPA 72C Remote Station<\/li>\n \t<li>CSFM<\/li>\n<\/ul><\/div><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>An Aprotex fire alarm control panel (FACP) utilizes the latest in a series of innovative, microprocessor-controlled fire detection devices. Each panel has a built-in programmer, self-diagnostics and remote upload\/download capability. All circuits are inherent power limited.Detection: FACP\u2019s vary in size in both Class A and Class B detection zones that support waterflow devices, smoke detectors, heat detectors, manual pull stations &#8230; <\/p>\n<div><a href=\"https:\/\/www.aprotex.com\/index.php\/fire-alarms\/\" class=\"more-link\">Read More<\/a><\/div>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-66","page","type-page","status-publish","hentry","no-post-thumbnail"],"_links":{"self":[{"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/pages\/66","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/comments?post=66"}],"version-history":[{"count":2,"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/pages\/66\/revisions"}],"predecessor-version":[{"id":443,"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/pages\/66\/revisions\/443"}],"wp:attachment":[{"href":"https:\/\/www.aprotex.com\/index.php\/wp-json\/wp\/v2\/media?parent=66"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}